Faced with the ever-changing fire situation in firefighting scenes, a fast and sufficient water supply is the key to extinguishing fires. The 2WM series solenoid valve has a deep insight into this demand and adopts a carefully calculated large-caliber design. This innovative design significantly increases the cross-sectional area through which water flows, effectively reduces the resistance of water flow inside the valve, and enables the fire water source to be released quickly and fully in an emergency to ensure the maximum efficiency of firefighting. At the same time, the large flow design also takes into account energy saving and environmental protection considerations. By optimizing the water flow path and reducing unnecessary energy consumption, the goal of both high efficiency and green is achieved.
Compared with traditional indirect-driven solenoid valves, the direct-acting structure adopted by the 2WM series solenoid valve is undoubtedly another highlight in its performance. The direct-acting structure omits the complex intermediate transmission mechanism, making the opening and closing actions of the valve more direct, rapid and reliable. This design not only simplifies the operating process and improves the response speed, but also significantly enhances the sensitivity and stability of the solenoid valve. Within the working pressure range of 0-1.0 Mpa (0-145 Psi), the 2WM series solenoid valve can easily cope with various complex fire protection system requirements, maintaining stable performance and reliable operation.
In the 2WM series solenoid valve, the perfect combination of large flow design and direct-acting structure is the key to its efficient water flow control. The large-caliber design ensures sufficient water supply, while the direct-acting structure provides a fast and direct valve action response. The two complement each other and together constitute the core competitiveness of this solenoid valve in the field of fire protection water flow control. In actual applications, when the power supply is stable and the automatic control system is working normally, the solenoid valve can automatically open or close according to the preset conditions accurately to achieve efficient and accurate water flow control. In emergencies such as power outages or automatic control system failures, users only need to simply rotate the red eye-catching handle to immediately switch to manual control mode, ensuring that the fire water source can be quickly connected in any emergency situation, winning precious time for fire fighting.